Filtration of hardening, gear-box oils, very dirty hydraulic oils.

Extra equipment:

  • Heating
  • Bag filter
Oil tank volume max. 2 000 liters
El. motor 0,75 kW
Normal flow volume 6 lit. / min.
Max. pressure 8 Bar
Heating 1 x 2,5 kW
Input and output G 1/2 "
Number of filltration units 2 pcs
Suction filter of pump protection 1 pc, 1 - 100 µm
Achieved purity class NAS 5/6
Achieved max. volume of water in oil after filtration 100 p.p.m.
By using dried elements less than 10 p.p.m.
Number of filtration elements
2 pcs
Maximum operating temperature 80 °C
Viscosity 6 - 220 cSt
Dimensions (length x height x width) 860 x 590 x 1050 mm
Connection to electricity 3x230V/400V (50Hz)
3x220V/440V (60Hz)