Ultra-fine filtration and flushing gear-boxes of robots in automatic mode by trial run gear-boxes.

Extra equipment: Laser particle measurement

Oil tank volume max. 1 000 liters
El. motor 2 x 0,25 kW
Normal flow volume 3 lit. / min.
Max. pressure 8 Bar
Input and output G 3/8 "
Number of filltration units 2 pcs
Suction filter of pump protection 1 pc 100 µm
Achieved purity class NAS 5/6
Achieved max. volume of water in oil after filtration 100 p.p.m.
After drying of elements lower than 10 p.p.m.
Number of filtration elements
2 pcs
Max. operating temperature 80 °C
Viscosity 6 - 220 cSt
Connection to electricity 3 x 230V/400V (50 Hz)

 